How the model was verified
Verified on 16 Nov 2026, against beam theory, on one reference beam.
The model
The model is static and linear-elastic. It bends a prismatic cantilever beam of solid rectangular section under one transverse point load at the free tip.
The solver is DOLFINx 0.11.0. The elements are P2 hex.
The default mesh is 60×6×3, which is 1080 elements on the reference beam.
The reference beam is 300 × 20 × 5 mm, Aluminium (6061-T6), 10 N. Beam theory gives 6.2609 mm at the tip and 18.000 MPa at mid-span.
Convergence on the reference beam
| Mesh | Elements | Tip deflection (mm) | Against theory | Change from mesh before | Stress at mid-span (MPa) | Against theory | Peak von Mises (MPa) |
|---|---|---|---|---|---|---|---|
| 20×2×1 | 40 | 6.1885 | −1.156% | First mesh | 18.418 | +2.323% | 32.93 |
| 40×4×2 | 320 | 6.2104 | −0.806% | +0.355% | 18.115 | +0.639% | 34.25 |
| 60×6×3Default mesh | 1080 | 6.2160 | −0.716% | +0.091% | 18.051 | +0.286% | 34.80 |
| 80×8×4 | 2560 | 6.2185 | −0.677% | +0.039% | 18.029 | +0.161% | 34.96 |
| 120×12×6 | 8640 | 6.2206 | −0.642% | +0.034% | 18.013 | +0.072% | 35.17 |
The model converges at 60×6×3: the tip deflection changes by less than 0.1% from the mesh before. That mesh is the default.
The two tolerances
What is not verified
The peak stress at the clamp
The FE peak includes the edge of the clamp. That value rises each time the mesh is refined and does not converge. Each result shows it with that caveat, and never marks it right or wrong.